HV BG4 EL

hv-bg4-el_out

HV BG4 EL

Medium velocity burner

Installed primarily in warm-up and pre-heat zones of roof or side fired tunnel kilns

Fuel For all liquid fuels with a viscosity of 6 cSt max.
Operation modes On / Off, Low Fire / High Fire, Modulating
Burner equipment Ignition rod for plug 6 mm, optical flame control sensor, internal oil preheater, combustion chamber SiSiC, flange plate mild steel, air inlet 2 x 60 mm/2“, oil inlet 1/4“, air measuring nipple 1/8“, all internal parts stainless steel, burner head and cover aluminium
Burner capacity 100 - 250 kW (depending on fuel pressure and nozzle size)
Oil pressure inlet 7 - 40 bar
Air pressure inlet 5 - 30 mbar
Lambda range 0.9 - 1.5
Temperature range
Operating temperature 0 - 1500°C
Combustion air temperature 0 - 300°C standard, 
300 - 500°C available upon request
Kiln wall thickness 600 - 3000 mm

 

All HTBS burners suitable for side firing and top firing