Choose your gear
HV BG4 EL
HV BG4 EL
Medium velocity burner
Installed primarily in warm-up and pre-heat zones of roof or side fired tunnel kilns
| Fuel | For all liquid fuels with a viscosity of 6 cSt max. |
| Operation modes | On / Off, Low Fire / High Fire, Modulating |
| Burner equipment | Ignition rod for plug 6 mm, optical flame control sensor, internal oil preheater, combustion chamber SiSiC, flange plate mild steel, air inlet 2 x 60 mm/2“, oil inlet 1/4“, air measuring nipple 1/8“, all internal parts stainless steel, burner head and cover aluminium |
| Burner capacity | 100 - 250 kW (depending on fuel pressure and nozzle size) |
| Oil pressure inlet | 7 - 40 bar |
| Air pressure inlet | 5 - 30 mbar |
| Lambda range | 0.9 - 1.5 |
| Temperature range |
Operating temperature 0 - 1500°C Combustion air temperature 0 - 300°C standard, 300 - 500°C available upon request |
| Kiln wall thickness | 600 - 3000 mm |
All HTBS burners suitable for side firing and top firing