HV BG3 G

HV BG3 G

HV BG3 G

High velocity burner

Installed primarily in warm-up and pre-heat zones of roof or side fired tunnel kilns

Fuel For all gaseous fuels
Operation modes On / Off, Low Fire / High Fire, Modulating, Micro Impulse
Burner equipment Ignition and ionisation rod for plug 6 mm (optical flame control sensor available on request), combustion chamber SiSiC, flange plate mild steel, air inlet 60 mm/2“, gas inlet 1/2“, air measuring nipple 1/8“, all internal parts stainless steel, burner head and cover aluminium
Burner capacity 20 - 250 kW (depending on fuel pressure and nozzle size)
Gas pressure inlet 0.1 - 1.0 bar
Air pressure inlet 10 - 40 mbar
Lambda range 0.9 - 20
Temperature range
Operating temperature 0 - 1500°C
Combustion air temperature 0 - 300°C standard, 
300 - 500°C available upon request
Kiln wall thickness 400 - 3000 mm

 

All HTBS burners suitable for side firing and top firing